Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.069
Filtrar
1.
Ann Plast Surg ; 92(4S Suppl 2): S96-S100, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556655

RESUMO

PURPOSE: Osseointegration (OI) is a novel alternative to traditional socket-suspended prostheses for lower-limb amputees, eliminating the socket-skin interface and allowing for weight bearing directly on the skeletal system. However, the stoma through which the implant attaches to the external prosthesis creates an ingress route for bacteria, and infection rates as high as 66% have been reported. The aims of this study are to classify infection management and long-term outcomes in this patient population to maximize implant salvage. METHODS: An institutional review board-approved retrospective analysis was performed on all patients who underwent lower-limb OI at our institution between 2017 and 2022. Demographic, operative, and outcome data were collected for all patients. Patients were stratified by the presence and severity of infection. Chi-square and t tests were performed on categorical and continuous data, respectively, using an alpha of 0.05. RESULTS: One hundred two patients met our study criteria; 62 had transfemoral OI and 40 had transtibial OI. Patients were followed for 23.8 months on average (range, 3.5-63.7). Osteomyelitis was more likely than soft tissue infection to be polymicrobial in nature (71% vs 23%, P < 0.05). Infections at the stoma were mostly (96%) managed with oral antibiotics alone, whereas deeper soft tissue infections also required intravenous antibiotics (75%) or operative washout (19%). Osteomyelitis was managed with intravenous antibiotics and required operative attention; 5 (71%) underwent washout and 2 (29%) underwent explantation. Both implants were replaced an average of 3.5 months after explantation. There was no correlation between history of soft tissue infection and development of osteomyelitis (P > 0.05). The overall implant salvage rate after infection was 96%. CONCLUSIONS: This study describes our institution's experience managing infection after OI and soft tissue reconstruction. Although infections do occur, they are easily treatable and rarely require operative intervention. Explantation due to infection is rare and can be followed up with reimplantation, reaffirming that OI is a safe and effective treatment modality.


Assuntos
Membros Artificiais , Osteomielite , Infecções dos Tecidos Moles , Humanos , Osseointegração , Implantação de Prótese , Estudos Retrospectivos , Infecções dos Tecidos Moles/etiologia , Membros Artificiais/efeitos adversos , Resultado do Tratamento , Antibacterianos/uso terapêutico , Osteomielite/etiologia , Osteomielite/cirurgia
2.
Arch Ital Urol Androl ; 96(1): 12214, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38572722

RESUMO

INTRODUCTION AND OBJECTIVES: Artificial urinary sphincter (AUS) is a treatment option for women with stress urinary incontinence (SUI) after failure of previous surgery or as a primary procedure in severe intrinsic sphincter deficiency (ISD). The aim of the study was to assess the long-term efficacy and risk factors for surgical revision and definitive explantation of AUS laparoscopic implantation in female patients. METHODS: A retrospective review of all women submitted to AUS implantation between April 2005 and March 2023 was conducted. The AUS was implanted via transperitoneal laparoscopic approach, by two experienced surgeons. The primary endpoint was postoperative continence. Continence was defined as no leakage and no pad usage or leakage and/or pad usage with no impact on social life and failure as leakage and/or pad usage impacting social life. As secondary outcomes, clinical predictive factors for AUS revision and definitive explantation were evaluated. RESULTS: In the last 18 years, females with a mean age of 68±12 years-old were submitted to laparoscopic implantation of AUS. Early overall complication rate was 16%, but only one case was Clavien-Dindo ≥3. After a median follow-up of 67 months, 22.2% of the patients needed a device revision, the majority due to mechanical device dysfunction. AUS definitive explantation was performed in 16%, mainly due to urethral/vaginal erosion (9.9%) and infection (6.2%). Patients with age ≥70 years and follow-up ≥10 years significantly predisposed for device revision. At the time of the last follow-up, 72% of the patients were keeping the urinary continency. CONCLUSIONS: Laparoscopic AUS implantation in females is an effective treatment for SUI due to ISD. Meanwhile, adequate patient selection, multidisciplinary evaluation and careful expectation management are essential to achieving good results, concerning their significant complication rate.


Assuntos
Laparoscopia , Doenças Uretrais , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Esfíncter Urinário Artificial/efeitos adversos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Laparoscopia/efeitos adversos , Uretra/cirurgia , Doenças Uretrais/cirurgia , Implantação de Prótese/métodos , Estudos Retrospectivos
3.
Arq Bras Oftalmol ; 87(6): e2021, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597522

RESUMO

Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


Assuntos
Doenças da Túnica Conjuntiva , Implantes para Drenagem de Glaucoma , Glaucoma , Criança , Humanos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular , Implantação de Prótese/métodos , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Pediatr Otorhinolaryngol ; 179: 111938, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38579403

RESUMO

INTRODUCTION: Endoscopic ossicular chain reconstruction (OCR) in adults has demonstrated equivalent outcomes to the traditional microscopic approach. Less data exist on endoscopic OCR outcomes in children, who have unique considerations including a smaller transcanal corridor and variable pathology. The purpose of this study was to investigate surgical and audiometric outcomes in children undergoing fully endoscopic and endoscopic-assisted OCR in both the short and long-term. METHODS: Retrospective review of all children (<17 years) who underwent endoscopic OCR at one tertiary care center between 2017 and 2021. Children undergoing primary and revision endoscopic OCR with either partial (PORP) and total ossicular reconstruction prostheses (TORP) were included. Children undergoing surgery for juvenile otosclerosis or congenital stapes fixation, or any child receiving a stapes prosthesis were excluded. Primary outcome measures were post-operative change in 4 frequency (500 Hz, 1, 2, 4 KHz) air conduction pure tone average (AC PTA) and change in air-bone gap (ABG). Secondary measures included need for readmission and/or revision surgery, complication rate, and surgery duration. RESULTS: Seventeen patients met inclusion criteria. Average age was 11.3 years (range, 5-17 years); 14 were male. A variety of fixed length, titanium total and partial prostheses were used. The most common prosthesis length was 2 mm (range 2-5 mm), and there were no intra- or perioperative complications. Mean long-term follow-up was 2.6 years. Most common pathology was congenital cholesteatoma (11/17, 64%), followed by chronic otitis media with tympanic membrane perforation (5/17, 29.4%), and extruded prosthesis (1/17, 5.9%). Intraoperatively, the most common finding was incus erosion (10/17, 58.8%), followed by malleus erosion (6/17, 35.3%), stapes erosion (4/17, 23.5%), and stapes absence (4/17, 23.5%). Eight children (47%) were reconstructed with PORPs, and 9 children (52.9%) were reconstructed with TORPs. Average ABG improved from 36.8 dB preoperatively to 19.9 dB postoperatively in the short-term and remained stable at 19.5 dB in the long-term. Average short-term ABG improvement was 4.2 dB for PORPs and 18 dB for TORPs. In the long-term, average ABG improved by 2.3 dB in PORPs and 13.4 dB in TORPs. PORPs had higher rates of ABG closure and lower AC PTAs than TORPs in the long-term. DISCUSSION: Endoscopic ossiculoplasty is a viable option in children presenting with ossicular erosion from various causes. Audiometric improvement following endoscopic partial and total ossicular reconstruction remains stable over time, with a preference towards partial in the long-term, and mirrors published outcomes for microscopic surgery.


Assuntos
Prótese Ossicular , Substituição Ossicular , Adulto , Humanos , Masculino , Criança , Feminino , Titânio , Implantação de Prótese , Orelha Média , Estudos Retrospectivos , Resultado do Tratamento
6.
J Orthop Surg Res ; 19(1): 210, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561755

RESUMO

OBJECTIVE: This study aims to biomimetic design a new 3D-printed lattice hemipelvis prosthesis and evaluate its clinical efficiency for pelvic reconstruction following tumor resection, focusing on feasibility, osseointegration, and patient outcomes. METHODS: From May 2020 to October 2021, twelve patients with pelvic tumors underwent tumor resection and subsequently received 3D-printed lattice hemipelvis prostheses for pelvic reconstruction. The prosthesis was strategically incorporated with lattice structures and solid to optimize mechanical performance and osseointegration. The pore size and porosity were analyzed. Patient outcomes were assessed through a combination of clinical and radiological evaluations. RESULTS: Multiple pore sizes were observed in irregular porous structures, with a wide distribution range (approximately 300-900 µm). The average follow-up of 34.7 months, ranging 26 from to 43 months. One patient with Ewing sarcoma died of pulmonary metastasis 33 months after surgery while others were alive at the last follow-up. Postoperative radiographs showed that the prosthesis's position was consistent with the preoperative planning. T-SMART images showed that the host bone was in close and tight contact with the prosthesis with no gaps at the interface. The average MSTS score was 21 at the last follow-up, ranging from 18 to 24. There was no complication requiring revision surgery or removal of the 3D-printed hemipelvis prosthesis, such as infection, screw breakage, and prosthesis loosening. CONCLUSION: The newly designed 3D-printed lattice hemipelvis prosthesis created multiple pore sizes with a wide distribution range and resulted in good osteointegration and favorable limb function.


Assuntos
Neoplasias Ósseas , Neoplasias Pélvicas , Humanos , Desenho de Prótese , Biomimética , Titânio , Implantação de Prótese/métodos , Neoplasias Pélvicas/cirurgia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/patologia , Estudos Retrospectivos , Resultado do Tratamento , Impressão Tridimensional
7.
Sci Rep ; 14(1): 7959, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575608

RESUMO

Cranial reconstructions are essential for restoring both function and aesthetics in patients with craniofacial deformities or traumatic injuries. Titanium prostheses have gained popularity due to their biocompatibility, strength, and corrosion resistance. The use of Superplastic Forming (SPF) and Single Point Incremental Forming (SPIF) techniques to create titanium prostheses, specifically designed for cranial reconstructions was investigated in an ovine model through microtomographic and histomorphometric analyses. The results obtained from the explanted specimens revealed significant variations in bone volume, trabecular thickness, spacing, and number across different regions of interest (VOIs or ROIs). Those regions next to the center of the cranial defect exhibited the most immature bone, characterized by higher porosity, decreased trabecular thickness, and wider trabecular spacing. Dynamic histomorphometry demonstrated differences in the mineralizing surface to bone surface ratio (MS/BS) and mineral apposition rate (MAR) depending on the timing of fluorochrome administration. A layer of connective tissue separated the prosthesis and the bone tissue. Overall, the study provided validation for the use of cranial prostheses made using SPF and SPIF techniques, offering insights into the processes of bone formation and remodeling in the implanted ovine model.


Assuntos
Membros Artificiais , Titânio , Ovinos , Animais , Humanos , Próteses e Implantes , Implantação de Prótese , Osteogênese , Carneiro Doméstico , Crânio/diagnóstico por imagem , Ligas , Teste de Materiais , Propriedades de Superfície
8.
J Oral Implantol ; 50(1): 9-17, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579116

RESUMO

The goal of this clinical report was to present an alternative to traditional flat bone reduction guides, using a custom-designed 3-dimensional (3D)-printed guide according to the future gingival margin of the planned dentition. A 61-year-old woman with concerns regarding her smile appearance was presented. The initial examination revealed excessive gingival show accompanied by excessive overjet. The dentition was in a failing situation. The proposed treatment plan, relying on the sufficient amount of bone and keratinized tissue, consisted of recontouring of the alveolar ridge and gingiva and placement of 6 implants and an FP-1 prosthesis after extraction of all remaining maxillary teeth. Digital smile design was completed, and a fully digitally guided surgery was planned. This consisted of using 3 surgical guides, starting with the fixation pin guide, continuing with the scalloped hard- and soft-tissue reduction guide, and finally the implant placement template. Following the surgery, the patient received a temporary restoration, and on the 4-month follow-up, a new polymethyl meta-acrylate temporary prosthesis was delivered. The patient's 7-month follow-up is presented in the article. The report of this triple-template guided surgery indicated that digital 3D planning is a considerably predictable tool to properly establish and evaluate future occlusal plane, smile line, and lip support. Scalloped guides seem to be an excellent alternative to conventional bone reduction guides since they require less bone removal and improve patient comfort during surgery.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Humanos , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Processo Alveolar , Gengiva/cirurgia , Implantação de Prótese , Prótese Dentária Fixada por Implante
9.
Sci Rep ; 14(1): 7989, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580783

RESUMO

Regardless of the species, birds are exposed to injuries that lead to amputation of part of the body structure and often euthanasia. Based on the need for new technologies that improve the quality of life of birds with locomotor problems, the present case reports aimed to describe the development of custom-made three-dimensional (3D) prostheses for domestic and wild birds that suffered amputation or malformation of the hind limb. Using the measurements of the bird, a digital model was created for 3D printing using fused deposition modeling technology (FDM) by the Brazilian company 3D Medicine. In this study we report the use of 3D prosthesis for the rehabilitation of three birds with locomotor disorders in Brazil, the animals adapted to the custom-made prosthesis with an improvement in quality of life, better distribution of body weight, locomotion, and landing. This study describes the development of 3D prostheses for birds in Brazil, the first report of this technology for these species, and the pioneering development of socket prostheses for small birds. 3D prostheses offer a high-efficiency solution to improve the quality of life of animals with amputations and malformations of the hind limbs. In addition, 3D technology provides valuable tools for veterinary medicine, developing custom-made models for the most different anatomical demands of animal patients.


Assuntos
Membros Artificiais , Qualidade de Vida , Animais , Aves , Impressão Tridimensional , Implantação de Prótese
10.
Arq Bras Oftalmol ; 87(4): e2022, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656019

RESUMO

We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.


Assuntos
Albinismo Oculocutâneo , Iris , Facoemulsificação , Acuidade Visual , Humanos , Albinismo Oculocutâneo/cirurgia , Albinismo Oculocutâneo/complicações , Feminino , Iris/cirurgia , Facoemulsificação/métodos , Resultado do Tratamento , Catarata/complicações , Catarata/congênito , Qualidade de Vida , Adulto , Órgãos Artificiais , Implantação de Prótese/métodos , Pessoa de Meia-Idade , Fotofobia/cirurgia , Fotofobia/etiologia
12.
G Ital Cardiol (Rome) ; 25(4): 252-261, 2024 Apr.
Artigo em Italiano | MEDLINE | ID: mdl-38526361

RESUMO

About 280 000 heart valve replacements are performed worldwide every year. Since the first prosthetic valve implantation in 1952 there have been notable developments. There are a lot of types of prosthetic valves that can be summarized into two categories: biological prosthetic valves or mechanical prosthetic valves. Biological prostheses, made of bovine or porcine pericardium, homografts, or autografts, degenerate over time becoming dysfunctional. Mechanical prostheses have a potentially unlimited lifespan but require oral anticoagulation which can affect patients' quality of life. Generally, biological prostheses are particularly suitable for elderly patients while mechanical prostheses for young people, with some distinctions. For example, in case of age <60 years, in the presence of preoperative oral anticoagulant therapy, metabolic syndrome, hemodialysis or hyperparathyroidism, a mechanical valve is the preference. The choice of the prosthesis in patients aged between 55 and 70 years is particularly challenging because the advantages and disadvantages of the two categories of prosthesis overlap in middle-aged patients. The choice of the prosthesis should be made after discussion with the surgeon, according to the patient's preferences, and keeping in mind the pros and cons of biological and mechanical prostheses.


Assuntos
Próteses e Implantes , Qualidade de Vida , Idoso , Pessoa de Meia-Idade , Humanos , Animais , Bovinos , Suínos , Adolescente , Implantação de Prótese , Anticoagulantes , Cateteres
13.
Arq Bras Oftalmol ; 87(3): e20230033, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537046

RESUMO

PURPOSE: This study aims to compare the initial ocular discomfort symptoms resulting from trabeculectomy and Ahmed glaucoma valve implantation surgeries. METHODS: A prospective comparative study was conducted. The evaluation of ocular discomfort employed a questionnaire designed to identify the frequency and severity of distinct symptoms: ocular pain, general discomfort, tearing, foreign body sensation, and burning. This questionnaire was administered prior to surgery as a baseline, and subsequently at 7, 30, and 90 days post-surgery. Simultaneously, the Ocular Surface Disease Index (OSDI) was applied at these same time intervals. RESULTS: The study encompassed a total of 17 patients (9 undergoing trabeculectomy and 8 undergoing Ahmed glaucoma valve implantation). The Ahmed glaucoma valve implantation group exhibited higher tearing levels at baseline (p=0.038). However, no statistically significant differences in symptoms were observed between the two surgeries at 7 and 30 days post-surgery. At the 90-day mark following surgery, patients who had undergone trabeculectomy reported a significantly higher foreign body sensation (p=0.004). Although OSDI scores did not differ between groups at baseline, the trabeculectomy group showed significantly higher OSDI scores than the Ahmed glaucoma valve implantation group at 7, 30, and 90 days after surgery (p<0.05). CONCLUSION: Post-surgery, patients who had undergone trabeculectomy experienced increased foreign body sensation. Trabeculectomy appears to cause greater early postoperative ocular discomfort compared to the Ahmed glaucoma valve implantation group.


Assuntos
Corpos Estranhos , Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Estudos Prospectivos , Pressão Intraocular , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/etiologia , Implantação de Prótese/efeitos adversos , Corpos Estranhos/complicações , Corpos Estranhos/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
14.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241236806, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38430070

RESUMO

PURPOSE: To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures. MATERIAL AND METHODS: This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated. RESULTS: The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation. CONCLUSION: The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.


Assuntos
Articulação do Cotovelo , Prótese de Cotovelo , Fraturas do Rádio , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Titânio , Implantação de Prótese , Articulação do Cotovelo/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Impressão Tridimensional , Resultado do Tratamento , Amplitude de Movimento Articular , Estudos Retrospectivos
15.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38462721

RESUMO

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X , Tomografia , Resultado do Tratamento
16.
Sci Rep ; 14(1): 6842, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514731

RESUMO

Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young's modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.


Assuntos
Membros Artificiais , Desenho de Prótese , Implantação de Prótese , Pressão , Fibra de Carbono , Impressão Tridimensional
17.
J Biomech ; 166: 112054, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38513398

RESUMO

The objective of this study was to define targeted reaching performance without visual information for transhumeral (TH) prosthesis users, establishing baseline information about extended physiological proprioception (EPP) in this population. Subjects completed a seated proprioceptive targeting task under simultaneous motion capture, using their prosthesis and intact limb. Eight male subjects, median age of 58 years (range 29-77 years), were selected from an ongoing screening study to participate. Five subjects had a left-side TH amputation, and three a right-side TH amputation. Median time since amputation was 9 years (range 3-54 years). Four subjects used a body-powered prosthetic hook, three a myoelectric hand, and one a myoelectric hook. The outcome measures were precision and accuracy, motion of the targeting hand, and joint angular displacement. Subjects demonstrated better precision when targeting with their intact limb compared to targeting with their prosthesis, 1.9 cm2 (0.8-3.0) v. 7.1 cm2 (1.3-12.8), respectively, p = 0.008. Subjects achieved a more direct reach path ratio when targeting with the intact limb compared to with the prosthesis, 1.2 (1.1-1.3) v. 1.3 (1.3-1.4), respectively, p = 0.039 The acceleration, deceleration, and corrective phase durations were consistent between conditions. Trunk angular displacement increased in flexion, lateral flexion, and axial rotation while shoulder flexion decreased when subjects targeted with their prosthesis compared to the intact limb. The differences in targeting precision, reach patio ratio, and joint angular displacements while completing the targeting task indicate diminished EPP. These findings establish baseline information about EPP in TH prosthesis users for comparison as novel prosthesis suspension systems become more available to be tested.


Assuntos
Membros Artificiais , Extremidade Superior , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Implantação de Prótese , Amputação Cirúrgica , Propriocepção , Desenho de Prótese
18.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
19.
Rev. argent. coloproctología ; 35(1): 40-44, mar. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1551683

RESUMO

En este reporte presentamos tres pacientes en quienes ocurrieron condiciones inflamatorias perianales tardías, luego de la administración de sustancias modeladoras no identificadas en los glúteos. El diagnóstico inicial y supuesto no fue correcto, ya que no se investigó durante la evaluación preliminar el antecedente de la administración de elementos modeladores. Recomendamos que los pacientes con patologías inflamatorias del ano, sobre todo aquellos cuyo curso es extraño, se les pregunte acerca de la administración de agentes modeladores en los glúteos. Esta práctica puede contribuir a la eficacia del diagnóstico de manifestaciones perianales caracterizadas por flogosis, que se presentan de forma inusual. (AU)


In this report we present three patients in which late perianal inflammatory conditions occurred after administration of unidentified modeling agents to the buttocks. The initial diagnosis was not correct because of the administration of modeling agents was not investigated during the initial eval-uation. We recommend inquiring patients with inflammatory pathologies of the anus, especially those whose course is unusual, about the adminis-tration of modeling agents to the buttocks. This approach can contribute to the efficiency of the diagnosis of perianal complaints characterized by inflammation, but rare in its appearance. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doenças do Ânus/cirurgia , Doenças do Ânus/etiologia , Biopolímeros/efeitos adversos , Nádegas/cirurgia , Doenças do Ânus/diagnóstico , Técnicas Cosméticas , Migração de Corpo Estranho , Implantação de Prótese/efeitos adversos
20.
Interv Cardiol Clin ; 13(2): 227-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432765

RESUMO

Mitral valve dysfunction is prevalent amongst older patients. Of those not suitable for surgical therapy, mitral transcatheter edge-to-edge repair (TEER) can treat as large proportion of patients, many are not suitable TEER candidates. As such, orthotopic transcatheter mitral valve replacement (TMVR) is an important innovation but it faces significant challenges. Orthotopic TMVR requires a prosthesis with stable anchoring, adequate sealing, minimal footprint in the left ventricle and long term durability. Multidisciplinary expertise in advanced imaging, surgery, heart failure are needed for success.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ventrículos do Coração , Implantação de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...